CONTROL CABLES THHN/THWN-2 600V PVC TC
Certifications and labels
CONTROL CABLES THHN/THWN-2 600V PVC TC
Soft copper conductor. Insulation in PVC and individual cover in Nylon, and Jacket in PVC.
Read more2 x 14AWG
Nexans ref.
- Conductor cross-section: 2.082 mm²
- Approximate weight: 103 kg/km
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 8.09 mm
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 8.802 Ohm/km
- Perm current rating in duct/buried 30°C: 25 A
3 x 14AWG
Nexans ref.
- Conductor cross-section: 2.082 mm²
- Approximate weight: 126 kg/km
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 8.53 mm
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 8.802 Ohm/km
- Perm current rating in duct/buried 30°C: 25 A
2 x 12AWG
Nexans ref.
- Conductor cross-section: 3.31 mm²
- Approximate weight: 138 kg/km
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 8.98 mm
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 5.566 Ohm/km
- Perm current rating in duct/buried 30°C: 30 A
4 x 14AWG
Nexans ref.
- Conductor cross-section: 2.082 mm²
- Approximate weight: 154 kg/km
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 9.26 mm
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 8.802 Ohm/km
- Perm current rating in duct/buried 30°C: 25 A
3 x 12AWG
Nexans ref.
- Conductor cross-section: 3.31 mm²
- Approximate weight: 174 kg/km
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 9.56 mm
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 5.566 Ohm/km
- Perm current rating in duct/buried 30°C: 30 A
5 x 14AWG
Nexans ref.
- Conductor cross-section: 2.082 mm²
- Approximate weight: 189 kg/km
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 10.09 mm
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 8.802 Ohm/km
- Perm current rating in duct/buried 30°C: 25 A
2 x 10AWG
Nexans ref.
- Conductor cross-section: 5.26 mm²
- Approximate weight: 208 kg/km
- Nominal insulation thickness: 0.51 mm
- Nominal outer diameter: 10.81 mm
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 3.485 Ohm/km
- Perm current rating in duct/buried 30°C: 40 A
4 x 12AWG
Nexans ref.
- Conductor cross-section: 3.31 mm²
- Approximate weight: 214 kg/km
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 10.38 mm
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 5.566 Ohm/km
- Perm current rating in duct/buried 30°C: 30 A
3 x 10AWG
Nexans ref.
- Conductor cross-section: 5.26 mm²
- Approximate weight: 263 kg/km
- Nominal insulation thickness: 0.51 mm
- Nominal outer diameter: 11.46 mm
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 3.485 Ohm/km
- Perm current rating in duct/buried 30°C: 40 A
5 x 12AWG
Nexans ref.
- Conductor cross-section: 3.31 mm²
- Approximate weight: 266 kg/km
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 11.38 mm
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 5.566 Ohm/km
- Perm current rating in duct/buried 30°C: 30 A
4 x 10AWG
Nexans ref.
- Conductor cross-section: 5.26 mm²
- Approximate weight: 325 kg/km
- Nominal insulation thickness: 0.51 mm
- Nominal outer diameter: 12.5 mm
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 3.485 Ohm/km
- Perm current rating in duct/buried 30°C: 40 A
5 x 10AWG
Nexans ref.
- Conductor cross-section: 5.26 mm²
- Approximate weight: 428 kg/km
- Nominal insulation thickness: 0.51 mm
- Nominal outer diameter: 14.58 mm
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 3.485 Ohm/km
- Perm current rating in duct/buried 30°C: 40 A
Description
Description
Standards
-
ProductUL 1277; UL 83
-
NationalNTC 1332
Application
Control cables THHN/THWN-2 are used in industrial facilities, for low voltage electrical energy distribution. Installation in dry or wet locations, in sumps, pipelines or direct burial, in places where there is no heavy traffic. Suitable for use in tray (TC) with external cover (jacket) resistant to UV rays (SR).
Construction
Conductor
Soft copper, concentric stranded class B.
Insulation
Polyvinyl Chloride PVC and induvidual cover in nylon, type THHN/THWN-2.
Jacket
Polyvinyl Chloride PVC, flame retardant, resistant to abrasion, heat and humidity.
Applicable Standards
- UL 83
- UL 1277, NTC 5916
Certificate
- CIDET N° 01668
- CIDET N° CP25_AA00038
- CIDET N° 04592
- CIDET N° CP25_AA00625
Operating Temperature
90 °C
Operating Voltage
600 V
Identification
Individually insulated conductors identified with numbers + black color base. Jacket in black color with marking and sequential meter by meter.
Packaging Unit
Reels by 500 m or 1000 m
Testing Conditions
- Ampacity for 90°C conductor temperature, 30°C ambient temperature. No more than three current carrying conductors in a duct or raceway. NTC 2050, table 310-16.
- Data indicated in this table are subject to normal manufacturing tolerances.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Fire safety characteristics
Fire safety characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania