5 x 14AWG

Description

Description

Standards

  • Product
    UL 1277; UL 83
  • National
    NTC 1332

Application

Control cables THHN/THWN-2 are used in industrial facilities, for low voltage electrical energy distribution. Installation in dry or wet locations, in sumps, pipelines or direct burial, in places where there is no heavy traffic. Suitable for use in tray (TC) with external cover (jacket) resistant to UV rays (SR).

Construction

Conductor

Soft copper, concentric stranded class B.

Insulation

Polyvinyl Chloride PVC and induvidual cover in nylon, type THHN/THWN-2.

Jacket

Polyvinyl Chloride PVC, flame retardant, resistant to abrasion, heat and humidity.

Applicable Standards

  • UL 83
  • UL 1277, NTC 5916

Certificate

  • CIDET N° 01668
  • CIDET N° CP25_AA00038
  • CIDET N° 04592
  • CIDET N° CP25_AA00625

Operating Temperature

90 °C

Operating Voltage

600 V

Identification

Individually insulated conductors identified with numbers + black color base. Jacket in black color with marking and sequential meter by meter.

Packaging Unit

Reels by 500 m or 1000 m

Testing Conditions

  • Ampacity for 90°C conductor temperature, 30°C ambient temperature. No more than three current carrying conductors in a duct or raceway. NTC 2050, table 310-16.
  • Data indicated in this table are subject to normal manufacturing tolerances.

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Insulation
PVC/Nylon
Outer sheath
PVC
Conductor flexibility
Class B
Conductor shape
Compressed

Dimensional characteristics

Dimensional characteristics

Conductor diameter
1.79 mm
Conductor cross-section
2.082 mm²
Inner sheath thickness
0.1 mm
Average sheath thickness
1.14 mm
Approximate weight
189 kg/km
Conductor cross-section (AWG/KCMIL)
14 AWG
Nominal insulation thickness
0.38 mm
Nominal outer diameter
10.09 mm
Number of cores
5

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
8.802 Ohm/km
Operating voltage
600 V
Perm current rating in duct/buried 30°C
25 A

Mechanical characteristics

Mechanical characteristics

Abrasion resistance
High

Usage characteristics

Usage characteristics

Maximum operating temperature
90 °C
Oil resistance
Yes
U.V resistance
Yes

Fire safety characteristics

Fire safety characteristics

Fire retardant
Method 1 - Vertical Tray (UL 2556/9.6)

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.