2x6+6AWG

Description

Description

Applications

These cables are used as input from the secondary distribution network to the connection equipment and their output to the service switch or totalizer, aerial installation or in ducts.

Note: Any other application or use not described above is considered prohibited.

Construction

Conductor

Soft copper conductors, concentrically stranded, Class B.

Insulation

Cross-linked polyethylene (XLPE) compound, flame retardant (FR), UV resistant (SR).

Neutral

Copper wires, helically applied in an alternating or oscillating SZ configuration, forming the concentric neutral.

Overall Jacket

External cover with cross-linked polyethylene (XLPE) compound, flame retardant (FR), resistant to abrasion, heat, moisture, and sunlight (SR).

Applicable Standards

  • ET-TD-ME01-23
  • NTC 4564, UL 854
  • NTC 1099-1, ICEA S-95-658

Certificate

  • CIDET N° 00416
  • CIDET N° 02400
  • CIDET N° CP25_00621

Operating Temperature

90 ºC

Operating Voltage

600 V

Identification

Identification of conductors:

  • 1 Phase: Black
  • 2 Phases: Black - Black/Red Stroke.
  • 3 Phases: Black/Yellow Stroke - Black/Blue Stroke - Black/Red Stroke 

Ampacity Conditions

  • Ampacity for ambient temperature 30°C, conductor temperature 90°C, no more than three current carrying conductors in a duct according to NTC 2050 Table 310.15(B)(16)
  • Data indicated in this table are subject to normal manufacturing tolerances.

NOTE:

  • The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
  • Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Inner covering
PVC
Insulation
XLPE
Outer sheath
XLPE
Conductor flexibility
Class B
Conductor shape
Compressed Stranded

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
13.3 mm²
Conductor diameter
4.528 mm
Nominal insulation thickness
1.52 mm
Number of cores
2
Inner sheath thickness
0.5 mm
Nominal outer sheath thickness
1.52 mm
Nominal outer diameter
20.38 mm
Approximate weight
689.52 kg/km

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
1.349 Ohm/km
Ampacity
75.0 A
Rated Voltage Uo/U (Um)
600 V

Mechanical characteristics

Mechanical characteristics

Abrasion resistance
Good

Usage characteristics

Usage characteristics

Weather resistance
Yes
Maximum operating temperature
90 °C
RoHS compliant
Yes
U.V resistance
UL 1581 - Sunlight Resistance

Fire safety characteristics

Fire safety characteristics

Flame retardant
IEC 60332-1

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close