2x10AWG

Nexans ref. 213917

  • Conductor cross-section: 5.26 mm²
  • Approximate weight: 196.4 kg/km
  • Conductor diameter: 2.87 mm
  • Nominal insulation thickness: 0.51 mm
  • Nominal outer diameter: 10.7 mm
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 3.582 Ohm/km
  • Perm current rating in air 30°C: 55 A
  • Perm current rating in duct/buried 30°C: 40 A
  • Ampacity: 40.0 A

 

3x10AWG

Nexans ref. 213918

  • Conductor cross-section: 5.27 mm²
  • Approximate weight: 246.81 kg/km
  • Conductor diameter: 2.87 mm
  • Nominal insulation thickness: 0.51 mm
  • Nominal outer diameter: 11.35 mm
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 3.582 Ohm/km
  • Perm current rating in air 30°C: 55 A
  • Perm current rating in duct/buried 30°C: 40 A
  • Ampacity: 40.0 A

 

4x10AWG

Nexans ref. 213919

  • Conductor cross-section: 5.28 mm²
  • Approximate weight: 306.45 kg/km
  • Conductor diameter: 2.87 mm
  • Nominal insulation thickness: 0.51 mm
  • Nominal outer diameter: 12.45 mm
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 3.582 Ohm/km
  • Perm current rating in air 30°C: 55 A
  • Perm current rating in duct/buried 30°C: 40 A
  • Ampacity: 40.0 A

 

4x12AWG

Nexans ref. 213922

  • Conductor cross-section: 3.31 mm²
  • Approximate weight: 202.38 kg/km
  • Conductor diameter: 2.27 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 10.32 mm
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 5.745 Ohm/km
  • Perm current rating in air 30°C: 40 A
  • Perm current rating in duct/buried 30°C: 30 A
  • Ampacity: 30.0 A

 

2x12AWG

Nexans ref. 213920

  • Conductor cross-section: 3.31 mm²
  • Approximate weight: 140.41 kg/km
  • Conductor diameter: 2.27 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 8.94 mm
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 5.745 Ohm/km
  • Perm current rating in air 30°C: 40 A
  • Perm current rating in duct/buried 30°C: 30 A
  • Ampacity: 30.0 A

 

3x12AWG

Nexans ref. 213921

  • Conductor cross-section: 3.31 mm²
  • Approximate weight: 164.22 kg/km
  • Conductor diameter: 2.27 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 9.46 mm
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 5.745 Ohm/km
  • Perm current rating in air 30°C: 40 A
  • Perm current rating in duct/buried 30°C: 30 A
  • Ampacity: 30.0 A

 

4x14AWG

Nexans ref. 213925

  • Conductor cross-section: 2.08 mm²
  • Approximate weight: 146.48 kg/km
  • Conductor diameter: 1.8 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 9.19 mm
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 9.022 Ohm/km
  • Perm current rating in air 30°C: 35 A
  • Perm current rating in duct/buried 30°C: 25 A
  • Ampacity: 25.0 A

 

2x14AWG

Nexans ref. 213923

  • Conductor cross-section: 2.08 mm²
  • Approximate weight: 98.55 kg/km
  • Conductor diameter: 1.8 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 8.0 mm
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 9.022 Ohm/km
  • Perm current rating in air 30°C: 35 A
  • Perm current rating in duct/buried 30°C: 25 A
  • Ampacity: 25.0 A

 

3x14AWG

Nexans ref. 213924

  • Conductor cross-section: 2.08 mm²
  • Approximate weight: 119.91 kg/km
  • Conductor diameter: 1.8 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 8.44 mm
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 9.022 Ohm/km
  • Perm current rating in air 30°C: 35 A
  • Perm current rating in duct/buried 30°C: 25 A
  • Ampacity: 25.0 A

 

2x16AWG

Nexans ref. 213926

  • Conductor cross-section: 1.31 mm²
  • Approximate weight: 75.86 kg/km
  • Conductor diameter: 1.43 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 7.26 mm
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 14.389 Ohm/km
  • Perm current rating in air 30°C: 24 A
  • Perm current rating in duct/buried 30°C: 18 A
  • Ampacity: 18.0 A

 

3x16AWG

Nexans ref. 213927

  • Conductor cross-section: 1.32 mm²
  • Approximate weight: 90.71 kg/km
  • Conductor diameter: 1.43 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 7.65 mm
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 14.389 Ohm/km
  • Perm current rating in air 30°C: 24 A
  • Perm current rating in duct/buried 30°C: 18 A
  • Ampacity: 18.0 A

 

4x16AWG

Nexans ref. 213928

  • Conductor cross-section: 1.33 mm²
  • Approximate weight: 109.28 kg/km
  • Conductor diameter: 1.43 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 8.29 mm
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 14.389 Ohm/km
  • Perm current rating in air 30°C: 24 A
  • Perm current rating in duct/buried 30°C: 18 A
  • Ampacity: 18.0 A

 

2x18AWG

Nexans ref. 213929

  • Conductor cross-section: 0.82 mm²
  • Approximate weight: 60.13 kg/km
  • Conductor diameter: 1.13 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 6.66 mm
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 23.122 Ohm/km
  • Perm current rating in air 30°C: 18 A
  • Perm current rating in duct/buried 30°C: 14 A
  • Ampacity: 14.0 A

 

3x18AWG

Nexans ref. 213930

  • Conductor cross-section: 0.82 mm²
  • Approximate weight: 70.48 kg/km
  • Conductor diameter: 1.13 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 7.0 mm
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 23.122 Ohm/km
  • Perm current rating in air 30°C: 18 A
  • Perm current rating in duct/buried 30°C: 14 A
  • Ampacity: 14.0 A

 

4x18AWG

Nexans ref. 213931

  • Conductor cross-section: 0.82 mm²
  • Approximate weight: 83.91 kg/km
  • Conductor diameter: 1.13 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 7.57 mm
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 23.122 Ohm/km
  • Perm current rating in air 30°C: 18 A
  • Perm current rating in duct/buried 30°C: 14 A
  • Ampacity: 14.0 A

 

Description

Description

Standards

  • Product
    ICEA S-95-658; NTC 1099-1

Application

Light duty cable used as a service cord for connection of portable tools and extension of appliances, in open installations and portable extensions with terminals. It can be used as a control cable where electrostatic shielding is not required.

Suitable for low voltage electrical power distribution, to be installed in sumps, installation in ducts and gutters, connection of boards and wiring in industrial or commercial buildings, for direct burial with light traffic, for installations in cable trays in dry, moisture, wet environments and outdoors. It can be used as a feeder cable for submersible pumps in water.

Note: Any other application or use not described above is considered prohibited.

Construction

Conductor

Extra-flexible soft copper conductors.

Insulation

Thermoplastic compound in polyvinyl chloride (PVC), flame retardant, fire retardant (FR), resistant to abrasion, heat and dry, moisture and wet environments. Compound free of hazardous substances (RoHS).

Individual Jacket

A Nylon cover resistant to contact with oils and petroleum derivatives such as gasoline is applied over the insulation.

Overall Jacket

External cover with thermoplastic compound in polyvinyl chloride (PVC), flame retardant, resistant to abrasion, moisture, impact, sunlight resistant (SR). Compound free of hazardous substances (RoHS).

Applicable Standards

ICEA S--95-658

NTC 1099-1

Certificate

  • CIDET N° 00408
  • CIDET N° CP25_AA00020

Operating Temperature

90°C in dry, moisture and wet places.

Operating Voltage

600V

 

Identification

  • Conductors identification:

Two conductors: black-white.

Three conductors: black-white-green.

Four conductors: black-white-red-green.

 

  • Jacket identification:

​Trace color according to the number of conductors and conductor size.

Ampacity Conditions

(*) Current capacity for 90°C conductor temperature, 30°C ambient temperature. No more than three current-carrying conductors in a conduit, raceway or directly buried. NTC 2050, Table 310.15(B)(16).

NOTE:

  • The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
  • Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.

Discover: NEXANS MULTIFLEX

Innovation Nexans Multiflex

Nexans Multiflex Gauges Identification

Nexans Multiflex Benefits

Nexans Multiflex Innovative Characteristics

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Flexible
Conductor material
Copper
Inner sheath
PVC
Insulation
PVC

Electrical characteristics

Electrical characteristics

Operating voltage
600 V

Mechanical characteristics

Mechanical characteristics

Crush resistance
ICEA S-95-658 (NTC 1099-1)
Mechanical resistance to impacts
ICEA S-95-658 (NTC 1099-1)

Usage characteristics

Usage characteristics

Maximum operating temperature
90 °C
U.V resistance
ICEA S-95-658 (NTC 1099-1), (720 hours)
Fire retardant
ICEA T-30-520
RoHS compliant
Yes
Short-circuit max. conductor temperature
150 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close