THHN/THWN-2 600V CT RoHS CABLE

Products

C.500kcmil

Nexans ref. 200416

  • Conductor diameter: 19.82 mm
  • Conductor cross-section: 253.35 mm²
  • Approximate weight: 2383.82 kg/km
  • Minimum outer sheath thickness: 0.2 mm
  • Nominal insulation thickness: 1.52 mm
  • Nominal outer diameter: 23.73 mm
  • Max. DC resistance of the conductor at 20°C: 0.071 Ohm/km
  • Ampacity: 430.0 A
  • Perm current rating in air 30°C: 700 A
  • Perm current rating in duct/buried 30°C: 430 A

 

C.350kcmil

Nexans ref. 200410

  • Conductor diameter: 16.57 mm
  • Conductor cross-section: 177.35 mm²
  • Approximate weight: 1711.76 kg/km
  • Minimum outer sheath thickness: 0.2 mm
  • Nominal insulation thickness: 1.52 mm
  • Nominal outer diameter: 20.46 mm
  • Max. DC resistance of the conductor at 20°C: 0.101 Ohm/km
  • Ampacity: 350.0 A
  • Perm current rating in air 30°C: 570 A
  • Perm current rating in duct/buried 30°C: 350 A

 

C.250kcmil

Nexans ref. 200406

  • Conductor diameter: 14.05 mm
  • Conductor cross-section: 126.68 mm²
  • Approximate weight: 1250.2 kg/km
  • Minimum outer sheath thickness: 0.2 mm
  • Nominal insulation thickness: 1.52 mm
  • Nominal outer diameter: 17.86 mm
  • Max. DC resistance of the conductor at 20°C: 0.142 Ohm/km
  • Ampacity: 290.0 A
  • Perm current rating in air 30°C: 455 A
  • Perm current rating in duct/buried 30°C: 290 A

 

C.4/0AWG

Nexans ref. 200402

  • Conductor diameter: 12.38 mm
  • Conductor cross-section: 107.22 mm²
  • Approximate weight: 1032.96 kg/km
  • Minimum outer sheath thickness: 0.18 mm
  • Nominal insulation thickness: 1.27 mm
  • Nominal outer diameter: 15.74 mm
  • Max. DC resistance of the conductor at 20°C: 0.167 Ohm/km
  • Ampacity: 260.0 A
  • Perm current rating in air 30°C: 405 A
  • Perm current rating in duct/buried 30°C: 260 A

 

C.3/0AWG

Nexans ref. 200398

  • Conductor diameter: 11.44 mm
  • Conductor cross-section: 85.03 mm²
  • Approximate weight: 836.57 kg/km
  • Minimum outer sheath thickness: 0.18 mm
  • Nominal insulation thickness: 1.27 mm
  • Nominal outer diameter: 14.35 mm
  • Max. DC resistance of the conductor at 20°C: 0.211 Ohm/km
  • Ampacity: 225.0 A
  • Perm current rating in air 30°C: 350 A
  • Perm current rating in duct/buried 30°C: 225 A

 

C.2/0AWG

Nexans ref. 200394

  • Conductor diameter: 9.82 mm
  • Conductor cross-section: 67.44 mm²
  • Approximate weight: 669.1 kg/km
  • Minimum outer sheath thickness: 0.18 mm
  • Nominal insulation thickness: 1.27 mm
  • Nominal outer diameter: 13.12 mm
  • Max. DC resistance of the conductor at 20°C: 0.266 Ohm/km
  • Ampacity: 195.0 A
  • Perm current rating in air 30°C: 300 A
  • Perm current rating in duct/buried 30°C: 195 A

 

C.1/0AWG

Nexans ref. 200390

  • Conductor diameter: 8.76 mm
  • Conductor cross-section: 53.51 mm²
  • Approximate weight: 540.17 kg/km
  • Minimum outer sheath thickness: 0.18 mm
  • Nominal insulation thickness: 1.27 mm
  • Nominal outer diameter: 12.03 mm
  • Max. DC resistance of the conductor at 20°C: 0.335 Ohm/km
  • Ampacity: 170.0 A
  • Perm current rating in air 30°C: 260 A
  • Perm current rating in duct/buried 30°C: 170 A

 

C.4AWG

Nexans ref. 200373

  • Conductor diameter: 5.61 mm
  • Conductor cross-section: 21.15 mm²
  • Approximate weight: 223.35 kg/km
  • Minimum outer sheath thickness: 0.15 mm
  • Nominal insulation thickness: 1.02 mm
  • Nominal outer diameter: 8.23 mm
  • Max. DC resistance of the conductor at 20°C: 0.534 Ohm/km
  • Ampacity: 95.0 A
  • Perm current rating in air 30°C: 140 A
  • Perm current rating in duct/buried 30°C: 95 A

 

C.2AWG

Nexans ref. 200383

  • Conductor diameter: 7.09 mm
  • Conductor cross-section: 33.63 mm²
  • Approximate weight: 344.94 kg/km
  • Minimum outer sheath thickness: 0.15 mm
  • Nominal insulation thickness: 1.02 mm
  • Nominal outer diameter: 9.72 mm
  • Max. DC resistance of the conductor at 20°C: 0.534 Ohm/km
  • Ampacity: 130.0 A
  • Perm current rating in air 30°C: 190 A
  • Perm current rating in duct/buried 30°C: 130 A

 

C.6AWG

Nexans ref. 200369

  • Conductor diameter: 4.44 mm
  • Conductor cross-section: 13.3 mm²
  • Approximate weight: 140.64 kg/km
  • Minimum outer sheath thickness: 0.13 mm
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 6.47 mm
  • Max. DC resistance of the conductor at 20°C: 1.35 Ohm/km
  • Ampacity: 75.0 A
  • Perm current rating in air 30°C: 105 A
  • Perm current rating in duct/buried 30°C: 75 A

 

C.8AWG

Nexans ref. 200363

  • Conductor diameter: 3.52 mm
  • Conductor cross-section: 8.37 mm²
  • Approximate weight: 92.88 kg/km
  • Minimum outer sheath thickness: 0.13 mm
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 5.53 mm
  • Max. DC resistance of the conductor at 20°C: 2.14 Ohm/km
  • Ampacity: 55.0 A
  • Perm current rating in air 30°C: 80 A
  • Perm current rating in duct/buried 30°C: 55 A

 

C.10AWG

Nexans ref. 200359

  • Conductor diameter: 2.79 mm
  • Conductor cross-section: 5.26 mm²
  • Approximate weight: 56.88 kg/km
  • Minimum outer sheath thickness: 0.1 mm
  • Nominal insulation thickness: 0.51 mm
  • Nominal outer diameter: 4.21 mm
  • Max. DC resistance of the conductor at 20°C: 3.41 Ohm/km
  • Ampacity: 40.0 A
  • Perm current rating in air 30°C: 55 A
  • Perm current rating in duct/buried 30°C: 40 A

 

C.12AWG

Nexans ref. 200354

  • Conductor diameter: 2.22 mm
  • Conductor cross-section: 3.31 mm²
  • Approximate weight: 35 kg/km
  • Minimum outer sheath thickness: 0.1 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 3.36 mm
  • Max. DC resistance of the conductor at 20°C: 5.43 Ohm/km
  • Ampacity: 30.0 A
  • Perm current rating in air 30°C: 40 A
  • Perm current rating in duct/buried 30°C: 30 A

 

C.14AWG

Nexans ref. 200351

  • Conductor diameter: 1.77 mm
  • Conductor cross-section: 2.08 mm²
  • Approximate weight: 23 kg/km
  • Minimum outer sheath thickness: 0.1 mm
  • Nominal insulation thickness: 0.38 mm
  • Nominal outer diameter: 2.89 mm
  • Max. DC resistance of the conductor at 20°C: 8.62 Ohm/km
  • Ampacity: 25.0 A
  • Perm current rating in air 30°C: 35 A
  • Perm current rating in duct/buried 30°C: 25 A

 

Description

Description

Standards

  • Product
    ASTM B 3; ASTM B 8; UL 83
  • National
    NTC 1332; NTC 307; NTC 359

Application

Low voltage electrical energy distribution; for use in electrical wiring of buildings, feeder circuits, branches and secondary industrial, commercial and residential indoor networks. Special for installations in abrasive sites or sites contaminated with oil, grease, gasoline, and other chemical substances.

They are suitable for installation in ducts, pipes, boards, and cable trays according to RETIE article 20.3 literal J, from 12 AWG gauge and larger.

Note: Any other application or use not described above is considered prohibited.

Construction

Conductor

Soft copper conductor, concentric stranded, Class B.

Insulation

Polyvinyl chloride (PVC), flame retardant (FR), resistant to heat, abrasion and humidity, resistant to sunlight (SR) in black, free of hazardous substances (RoHS).

Jacket

External cover in polyamide (nylon), resistant to gasoline and oils (GR II).

Applicable Standars

UL 83, NTC 1332

Certificate

RETIE  N° 01864

RETIE  N° 00406

Operating Temperature

90°C dry and wet places.

Operating Voltage

600 V

Identification

Insulation in colors according to the manufacturing standard.

AMPACITY CONDITIONS

(*) ​Current capacity for 90°C conductor temperature, 30°C ambient temperature. No more than three current-carrying conductors in a conduit, raceway or directly buried. NTC 2050, Table 310.15(B)(16).

(**) Current capacity for 90°C conductor temperature, 30°C ambient temperature. Single conductor in free air. NTC 2050, Table 310.15(B)(17).

NOTE:

  • The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
  • Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Insulation
PVC
Outer sheath
Nylon
Conductor flexibility
Class B

Electrical characteristics

Electrical characteristics

Operating voltage
600 V

Usage characteristics

Usage characteristics

Chemical resistance
Excellent
Oil resistance
UL 83 - GR II
Maximum operating temperature
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
150 °C
Fire retardant
VW-1, Method 1-Vertical Tray (UL 2556)
RoHS compliant
Yes

Resources

Resources

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close