SINTOX AL S8000 LHFR-LS 75°C

Products

C. 2 AWG AA8000

Nexans ref. 10043934

  • Approximate weight: 164.14 kg/km
  • Conductor cross-section: 33.6 mm²
  • Conductor diameter: 7.13 mm
  • Nominal insulation thickness: 1.52 mm
  • Nominal outer diameter: 10.27 mm
  • Ampacity: 90.0 A
  • Max. DC resistance of the conductor at 20°C: 0.873 Ohm/km
  • Gases corrosivity:

 

C. 2/0 AWG AA8000

Nexans ref. 10043937

  • Approximate weight: 303.94 kg/km
  • Conductor cross-section: 67.4 mm²
  • Conductor diameter: 9.9 mm
  • Nominal insulation thickness: 2.03 mm
  • Nominal outer diameter: 14.06 mm
  • Ampacity: 135.0 A
  • Max. DC resistance of the conductor at 20°C: 0.434 Ohm/km
  • Gases corrosivity:

 

C. 250 KCMIL AA8000

Nexans ref. 10043941

  • Approximate weight: 546.29 kg/km
  • Conductor cross-section: 127 mm²
  • Conductor diameter: 14.07 mm
  • Nominal insulation thickness: 2.41 mm
  • Nominal outer diameter: 18.97 mm
  • Ampacity: 205.0 A
  • Max. DC resistance of the conductor at 20°C: 0.232 Ohm/km
  • Gases corrosivity:

 

C. 3/0 AWG AA8000

Nexans ref. 10038791

  • Approximate weight: 350 kg/km
  • Conductor cross-section: 85.03 mm²
  • Conductor diameter: 11.94 mm
  • Nominal insulation thickness: 2.03 mm
  • Nominal outer diameter: 14.7 mm
  • Ampacity: 155.0 A
  • Max. DC resistance of the conductor at 20°C: 0.339 Ohm/km
  • Gases corrosivity:

 

C. 350Kcmil AA8000

Nexans ref. 10038847

  • Approximate weight: 691 kg/km
  • Conductor cross-section: 177.3 mm²
  • Conductor diameter: 17.3 mm
  • Nominal insulation thickness: 2.41 mm
  • Nominal outer diameter: 20.5 mm
  • Ampacity: 250.0 A
  • Max. DC resistance of the conductor at 20°C: 0.183 Ohm/km
  • Gases corrosivity:

 

C. 4 AWG AA8000

Nexans ref. 10043933

  • Approximate weight: 115.9 kg/km
  • Conductor cross-section: 21.2 mm²
  • Conductor diameter: 5.65 mm
  • Nominal insulation thickness: 1.52 mm
  • Nominal outer diameter: 8.79 mm
  • Ampacity: 65.0 A
  • Max. DC resistance of the conductor at 20°C: 1.387 Ohm/km
  • Gases corrosivity:

 

C. 4/0 AWG AA8000

Nexans ref. 10043940

  • Approximate weight: 453.64 kg/km
  • Conductor cross-section: 107 mm²
  • Conductor diameter: 12.9 mm
  • Nominal insulation thickness: 2.03 mm
  • Nominal outer diameter: 17.06 mm
  • Ampacity: 180.0 A
  • Max. DC resistance of the conductor at 20°C: 0.274 Ohm/km
  • Gases corrosivity:

 

C. 500Kcmil AA8000

Nexans ref. 10038848

  • Approximate weight: 970 kg/km
  • Conductor cross-section: 253 mm²
  • Conductor diameter: 19.89 mm
  • Nominal insulation thickness: 2.41 mm
  • Nominal outer diameter: 24.8 mm
  • Ampacity: 310.0 A
  • Max. DC resistance of the conductor at 20°C: 0.116 Ohm/km
  • Gases corrosivity:

 

C. 6 AWG AA8000

Nexans ref. 10043892

  • Approximate weight: 83.85 kg/km
  • Conductor cross-section: 13.3 mm²
  • Conductor diameter: 4.48 mm
  • Nominal insulation thickness: 1.52 mm
  • Nominal outer diameter: 7.62 mm
  • Ampacity: 50.0 A
  • Max. DC resistance of the conductor at 20°C: 2.19 Ohm/km
  • Gases corrosivity:

 

C.1/0 AWG AA8000

Nexans ref. 10043936

  • Approximate weight: 253.4 kg/km
  • Conductor cross-section: 53.5 mm²
  • Conductor diameter: 8.79 mm
  • Nominal insulation thickness: 2.03 mm
  • Nominal outer diameter: 12.95 mm
  • Ampacity: 120.0 A
  • Max. DC resistance of the conductor at 20°C: 0.549 Ohm/km
  • Gases corrosivity: IEC 60754-2

 

Description

Description

Application

Cables for low voltage electrical energy distribution, installations in buildings, inside premises, control panels and electronic circuits. Suitable for places with a high concentration of people, where conductors with a low halogen content and low smoke emission are required, which in the event of a fire will not generate toxic or corrosive gases that may affect the health of people and the condition of equipment and circuits electronics. The cables can be used for installations mentioned in NTC 2050 Article 310.

Suitable for installation in cable trays according to RETIE article 20.3, literal J, from 12 AWG gauge and larger.

Construction

Conductor

S8000 Aluminium

Insulation

Low halogen (LH – Low Halogen), flame retardant (FR – Flame Retardant), low smoke emission (LS – Low Smoke) opaque, dense, toxic and corrosive thermoplastic compound.

Applicable Standards

NTC 6182

Certificate

RETIE N° 07511

RETIE N° 05915

Operating Temperature

75°C

Operating Voltage

600V

Ampacity Conditions

  • Ampacity for ambient temperature 30°C, conductor temperature 75°C, no more than three carrying current conductors in a duct. According to table 310.15(B)(16) NTC 2050.

NOTE:

  • The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
  • Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Class B
Conductor material
Aluminum 8000 series
Conductor shape
Compressed
Insulation
Halogen free polyolefin

Dimensional characteristics

Dimensional characteristics

Number of cores
1

Electrical characteristics

Electrical characteristics

Operating voltage
600 V

Mechanical characteristics

Mechanical characteristics

Abrasion resistance
Good

Usage characteristics

Usage characteristics

Fire retardant
IEC 60332-3-24 (cat C)
Smoke density
Low

Resources

Resources

Selling & delivery Information

Marking

CENTELSA by NEXANS < Calibre AWG / Kcmil >  AA8000 SINTOX LHFR-LS 600 V 75°C CT - HECHO EN COLOMBIA [M].

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close