- Markets
- Catalogue
- Services and solutions
-
Company
- Company
- Nexans in Colombia
- Compliance Programs
- Career
- The values of the New Nexans
- The values of the New Nexans
- Our mission and purpose
- Centelsa by Nexans History
- Contact Us Centelsa by Nexans
- Locations
- Nexans in Colombia
- Sustainability
- Cuando es original, SE NOTA.
- Whistleblowing : Ethics alert system
- Contac us
- Newsroom
- Tools & Resources
- Documents
- Nexans Insights
- Search
- Contact us
- Compare
- Sign in
NA2XSY 20/35 kV PH+PC; ABNT NBR 6251; ABNT NBR 7286; Anti-rodent
NA2XSY 20/35 kV 240 mm2 PH16
Nexans ref. P00034148-0
- Conductor cross-section: 240 mm²
- Conductor diameter: 18.0 mm
- Diameter over insulation: 37.1 mm
- Diameter over screen: 40.5 mm
- Diameter over Sheath: 45.5 mm
- Approximate weight: 2115 kg/km
NA2XSY 20/35 kV 300 mm2 PH16
Nexans ref. P00034149-0
- Conductor cross-section: 300 mm²
- Conductor diameter: 20.4 mm
- Diameter over insulation: 39.5 mm
- Diameter over screen: 42.8 mm
- Diameter over Sheath: 48 mm
- Approximate weight: 2385 kg/km
NA2XSY 20/35 kV 400 mm2 PH16
Nexans ref. P00034150-0
- Conductor cross-section: 400 mm²
- Conductor diameter: 23.1 mm
- Diameter over insulation: 42.2 mm
- Diameter over screen: 45.5 mm
- Diameter over Sheath: 50.9 mm
- Approximate weight: 2757 kg/km
NA2XSY 20/35 kV 500 mm2 PH16
Nexans ref. P00034151-0
- Conductor cross-section: 500 mm²
- Conductor diameter: 26.2 mm
- Diameter over insulation: 45.3 mm
- Diameter over screen: 48.7 mm
- Diameter over Sheath: 54.3 mm
- Approximate weight: 3220 kg/km
NA2XSY 20/35 kV 630 mm2 PH16
Nexans ref. P00034152-0
- Conductor cross-section: 630 mm²
- Conductor diameter: 29.8 mm
- Diameter over insulation: 48.9 mm
- Diameter over screen: 52.3 mm
- Diameter over Sheath: 58 mm
- Approximate weight: 3775 kg/km
Description
Description
Applications
Power distribution in medium voltage. In power plants and electrical substations, industrial and operation installations, in residential areas and mining installations, in dry or wet locations.
CONSTRUCTION
1. Conductor: Compact round aluminium 1350, class 2.
2. Inner semi-conductor: Extruded.
3. Insulation: Cross linked polyethylene XLPE-TR (Tree retardant).
4. External semi-conductor: Extruded strippable.
These last three components extruded CV (continuous vulcanization) triple extrusion in dry cure process.
5. Screen: Copper wires + copper tape in open helix.
6. Tape: Polyester tape.
7. Outer sheath: Compound polyvinyl chloride PVC with antirodent compound.
MAIN CHARACTERISTICS
Excellent properties against heat aging. Resistance to abrasion, moisture and sunlight. Adequate resistance to greases and oils. Flame retardant. Resistance to attack by rodents.
CROSS SECTION
From 240 mm2 up to 630 mm2.
PACKING
Non returnable wooden reels.
COLOUR
Insulation: Natural.
Outer sheath: Black.
PRODUCT STANDARDS
NTP-IEC 60228: Conductors of insulated cables.
IEC 60228: Conductors of insulated cables.
ABNT NBR 6251: Insulated power cables, for rated voltages 1 kV up to 35 kV - Constructive requirements.
ABNT NBR 7287: Power cables extruded cross-linked polyethylene insulated power cable for rated voltages from 1 up to 35 kV - Performace requirements.
TESTING STANDARDS
IEC 60332-1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame.
UL 2556: Wire and Cable Test Methods. Section 9.3:FT1 (Vertical-Specimen) Flame Test.
IEC 60811-401: Thermal ageing methods. Ageing in an air oven.
IEC 60811-402: Water absorption tests.
IEC 60811-409: Loss of mass test for thermoplastic insulations and sheaths.
IEC 60811-501: Test for determining the mechanical properties.
IEC 60811-502: Shrinkage test for insulations.
IEC 60811-504: Bending test at low temperature for insulation and sheaths.
IEC 60811-505: Elongation at low temperature for insulations and sheaths.
IEC 60811-506: Impact test at low temperature for insulations and sheaths.
IEC 60811-507: Hot set test for cross-linked materials.
IEC 60811-508: Pressure test at high temperature for insulation and sheaths.
IEC 60811-509: Test for resistance of insulations and sheaths to cracking.
ICEA S-93-639: 5-46 kV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy. Section 9.4.2: Oil Immersion Test.
UL 2556: Wire and Cable Test Methods. Section 4.2.8.5: Carbon-Arc and Xenon-Arc Tests- Sunlight resistance.
Calculation of Current Condition Single core Medium Voltage
CALCULATION OF CURRENT CONDITION BASED ON ABNT NBR 14039
Maximum conductor temperature: 90°C.
Ambient air temperature: 30°C.
Ground temperature: 20°C.
Depth of laying: 0,9 m.
Thermal resistivity of soil: 1,5 K.m/W.
Thermal resistivity of duct: 1,2 K.m/W.
RECOMMENDATION - M.V. CABLE ACCESSORIES
Technical information presented herein is for referential purposes. Actual dimensions and construction details will be available only with the test reports for each manufacturing order. For "Make To Stock" products it is recommended to measure relevant dimensions directly on the cable. Nexans will not assume responsibility for connector selection.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Marking:
INDECO S.A. NA2XSY 20/35 kV - Cross section - PH(Screen section) - Year - Sequential length.
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania