- Markets
- Catalogue
- Services and solutions
- Company
- Newsroom
- Tools & Resources
- Documents
- Search
- Contact us
- Compare
- Sign in
TECK 90 600 V Single core
TECK 90 600 V Single core
General application as power cable in low voltage.
Read moreTECK 90 600 V 2 AWG+1x6 AWG
Nexans ref. P00015937-3
- Packaging: Cut to length (m)
- Conductor diameter: 6.8 mm
- Diameter over Sheath: 19.1 mm
- Approximate weight: 699 kg/km
TECK90 600 V 350kcmil+1x1 AWG
Nexans ref. P00015947-2
- Conductor diameter: 15.8 mm
- Diameter over Sheath: 33.5 mm
- Approximate weight: 2851 kg/km
Description
Description
Standards
-
NationalCSA C22.2 N° 03-01; CSA C22.2 N° 131; CSA C22.2 N° 2556; CSA C22.2 N° 38; UL 2556
Application:
General application in low voltage distribution networks in operating stations where high mechanical strength is required. The interlocked aluminum armour gives greater flexibility compared to the traditional steel armour and the type of conformation of the same make has a high resistance to loads that could be placed on it.Class I, Div.2 and Class II, Div.2 hazardous locations per NEC.
Construction:
1. Conductor: Compact soft copper, class B.
2. Insulation: Cross linked polyethylene XLPE.
3. Bare grounding conductor: Soft copper wires aplied in concentric form.
4. Inner covering: Anti-flame compound polyvinyl chloride PVC.
5. Armour: Interlocked aluminum tape.
6. Outer sheath: Anti-flame compound polyvinyl chloride PVC.
Main characteristics:
Resistance to abrasion and oils. Resistance to weather and sunlight. Its armour provides additional mechanical protection and provides greater flexibility compared with other types of armour. Does not propagate the FT-1 flame. Fire retardant according to C22.2 No 0.3-01/FT-4. Resistance to attack by rodents.
Gauge:
2 AWG and 350 kcmil.
Marking:
For gauges equal to or smaller than 8 AWG: INDECO S.A. TECK90(XLPE) (Gauge phase cond. + Gauge ground. cond.) 0,6 kV -25C FT1 FT4 SR CSA 255079 - Year - Sequential length.
For gauges higher than 8 AWG: INDECO S.A. TECK90(XLPE) (Gauge phase cond. + Gauge ground. cond.) 0,6 kV -40C FT1 FT4 SR CSA 255079 - Year - Sequential length.
Packing:
Non returnable wooden reels.
Colour:
Insulation: Black.
Outer sheath: Black.
International standards
CSA C22.2 Nº 131-14: Type TECK 90 cable.
CSA C22.2 Nº 38-14: Thermoset-insulated wires and cables.
SA C22.2 Nº 03-01: Test methods for electrical wires and cables.
CSA C22.2 Nº 2556-15: Wire and cable test methods.
UL 2556: Wire and Cable Test Methods. Section 9.3: FT1 (Vertical-Specimen) Flame Test.
UL 2556: Wire and Cable Test Methods. Section 4.2.8.5: Carbon-Arc and Xenon-Arc Tests- Sunlight resistance.
BENDING RADIUS WHEN INSTALLED
R = f x D
R: Bending radius when installed (mm).
f: Multiplicative factor.
D: Cable nominal outer diameter (mm).
Calculation of Current Condition TECK 90
BASED ON CEC, PART 1, TABLE 1
Maximum conductor temperature: 90°C.
Ambient temperature: 30°C.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania