- Markets
- Catalogue
- Services and solutions
- Company
- Newsroom
- Tools & Resources
- Documents
- Search
- Contact us
- Compare
- Sign in
ENERGYFLEX photovoltaic Cable - H1Z2Z2-K
ENERGYFLEX photovoltaic Cable - H1Z2Z2-K
Flexible tinned copper conductor, with insulation and thermostable cover HF LS free of hazardous substances (RoHS).
Read more16 mm2 NEW
Nexans ref. 10046026
- Packaging: Drum (m)
- Approximate weight: 171 kg/km
- Conductor cross-section: 16 mm²
- Conductor diameter: 5.41 mm
- Insulation sheath thickness: 0.9 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer diameter: 8.7 mm
- Nominal outer sheath thickness: 0.9 mm
- Ampacity: 132.0 A
- Max. DC resistance of the conductor at 20°C: 1.24 Ohm/km
25 mm2 NEW
Nexans ref. 10048947
- Packaging: Drum (m)
- Approximate weight: 265 kg/km
- Conductor cross-section: 25 mm²
- Conductor diameter: 6.81 mm
- Insulation sheath thickness: 1.0 mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer diameter: 10.8 mm
- Nominal outer sheath thickness: 1.0 mm
- Ampacity: 176.0 A
- Max. DC resistance of the conductor at 20°C: 0.795 Ohm/km
Cable 10 mm2 H1Z2Z2-K NE
Nexans ref. 10045084
- Approximate weight: 112 kg/km
- Conductor cross-section: 10 mm²
- Conductor diameter: 4.44 mm
- Insulation sheath thickness: 0.8 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer diameter: 7.59 mm
- Nominal outer sheath thickness: 0.8 mm
- Ampacity: 98.0 A
- Max. DC resistance of the conductor at 20°C: 1.95 Ohm/km
Cable 10 mm2 H1Z2Z2-K RO
Nexans ref. 10045086
- Approximate weight: 112 kg/km
- Conductor cross-section: 10 mm²
- Conductor diameter: 4.44 mm
- Insulation sheath thickness: 0.8 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer diameter: 7.59 mm
- Nominal outer sheath thickness: 0.8 mm
- Ampacity: 98.0 A
- Max. DC resistance of the conductor at 20°C: 1.95 Ohm/km
Cable 4 mm2 H1Z2Z2-K Ne
Nexans ref. 10042414
- Approximate weight: 51 kg/km
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.49 mm
- Insulation sheath thickness: 0.8 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer diameter: 5.73 mm
- Nominal outer sheath thickness: 0.8 mm
- Ampacity: 55.0 A
- Max. DC resistance of the conductor at 20°C: 5.09 Ohm/km
Cable 4 mm2 H1Z2Z2-K Ro
Nexans ref. 10042413
- Approximate weight: 51 kg/km
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.49 mm
- Insulation sheath thickness: 0.8 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer diameter: 5.73 mm
- Nominal outer sheath thickness: 0.8 mm
- Ampacity: 55.0 A
- Max. DC resistance of the conductor at 20°C: 5.09 Ohm/km
Cable 6 mm2 H1Z2Z2-K Ne
Nexans ref. 10043330
- Approximate weight: 71 kg/km
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.15 mm
- Insulation sheath thickness: 0.8 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer diameter: 6.3 mm
- Nominal outer sheath thickness: 0.8 mm
- Ampacity: 70.0 A
- Max. DC resistance of the conductor at 20°C: 3.39 Ohm/km
Cable 6 mm2 H1Z2Z2-K Ro
Nexans ref. 10043332
- Packaging: Drum (1000m)
- Approximate weight: 71 kg/km
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.15 mm
- Insulation sheath thickness: 0.8 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer diameter: 6.3 mm
- Nominal outer sheath thickness: 0.8 mm
- Ampacity: 70.0 A
- Max. DC resistance of the conductor at 20°C: 3.39 Ohm/km
Description
Description
Standards
-
InternationalEN 50618
Application
Supply of low voltage 1.5 kV DC circuits in photovoltaic solar energy installations where weather resistance characteristics are required.
Ideal for connection between strings of photovoltaic solar panels and as a main power supply for connecting DC / AC inverters.
Construction
Conductor
Flexible soft tinned copper conductor class 5
Insulation
Thermostable compound free of halogens (HF) and low smoke emission (LS) toxic and corrosive.
Jacket
Halogen free (HF), flame retardant (FR) and UV resistant thermosetting compound, suitable for AD7 immersion.
Applicable Standards
- EN 50618
- IEC 62930
Certificate
RETIE N° 07225
RETIE N° 07215
Operating Temperature
90°C / 120°C (Max. 20.000 h)
Max. conductor temperature based on EN 60216-1:
-40°C to +120°C
Ambient temperature range according to EN 50618:
-40°C to +90°C
Operating Voltage
1 kV AC
1.5 kV DC
Max. Operation Voltage
1.2 kV AC
1.8 kV DC
Ampacity Conditions
- Current capacity a single cable outdoors, at 60 ºC According to the norm in 50618- table A.3(see Table A.4 for
other ambient temperatures) - The expected period of use at a maximum conductor temperature of 120°C and at a maximum ambient temperature of 90°C is limited to 20,000 h.
- Data indicated in this table are subject to normal manufacturing tolerances.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Find a Distributor
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania