ENERGYFLEX photovoltaic Cable - H1Z2Z2-K

Products

16 mm2 NEW

Nexans ref. 10046026

  • Packaging: Drum (m)
  • Approximate weight: 171 kg/km
  • Conductor cross-section: 16 mm²
  • Conductor diameter: 5.41 mm
  • Insulation sheath thickness: 0.9 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer diameter: 8.7 mm
  • Nominal outer sheath thickness: 0.9 mm
  • Ampacity: 132.0 A
  • Max. DC resistance of the conductor at 20°C: 1.24 Ohm/km

 

25 mm2 NEW

Nexans ref. 10048947

  • Packaging: Drum (m)
  • Approximate weight: 265 kg/km
  • Conductor cross-section: 25 mm²
  • Conductor diameter: 6.81 mm
  • Insulation sheath thickness: 1.0 mm
  • Nominal insulation thickness: 0.9 mm
  • Nominal outer diameter: 10.8 mm
  • Nominal outer sheath thickness: 1.0 mm
  • Ampacity: 176.0 A
  • Max. DC resistance of the conductor at 20°C: 0.795 Ohm/km

 

Cable 10 mm2 H1Z2Z2-K NE

Nexans ref. 10045084

  • Approximate weight: 112 kg/km
  • Conductor cross-section: 10 mm²
  • Conductor diameter: 4.44 mm
  • Insulation sheath thickness: 0.8 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer diameter: 7.59 mm
  • Nominal outer sheath thickness: 0.8 mm
  • Ampacity: 98.0 A
  • Max. DC resistance of the conductor at 20°C: 1.95 Ohm/km

 

Cable 10 mm2 H1Z2Z2-K RO

Nexans ref. 10045086

  • Approximate weight: 112 kg/km
  • Conductor cross-section: 10 mm²
  • Conductor diameter: 4.44 mm
  • Insulation sheath thickness: 0.8 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer diameter: 7.59 mm
  • Nominal outer sheath thickness: 0.8 mm
  • Ampacity: 98.0 A
  • Max. DC resistance of the conductor at 20°C: 1.95 Ohm/km

 

Cable 4 mm2 H1Z2Z2-K Ne

Nexans ref. 10042414

  • Approximate weight: 51 kg/km
  • Conductor cross-section: 4 mm²
  • Conductor diameter: 2.49 mm
  • Insulation sheath thickness: 0.8 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer diameter: 5.73 mm
  • Nominal outer sheath thickness: 0.8 mm
  • Ampacity: 55.0 A
  • Max. DC resistance of the conductor at 20°C: 5.09 Ohm/km

 

Cable 4 mm2 H1Z2Z2-K Ro

Nexans ref. 10042413

  • Approximate weight: 51 kg/km
  • Conductor cross-section: 4 mm²
  • Conductor diameter: 2.49 mm
  • Insulation sheath thickness: 0.8 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer diameter: 5.73 mm
  • Nominal outer sheath thickness: 0.8 mm
  • Ampacity: 55.0 A
  • Max. DC resistance of the conductor at 20°C: 5.09 Ohm/km

 

Cable 6 mm2 H1Z2Z2-K Ne

Nexans ref. 10043330

  • Approximate weight: 71 kg/km
  • Conductor cross-section: 6 mm²
  • Conductor diameter: 3.15 mm
  • Insulation sheath thickness: 0.8 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer diameter: 6.3 mm
  • Nominal outer sheath thickness: 0.8 mm
  • Ampacity: 70.0 A
  • Max. DC resistance of the conductor at 20°C: 3.39 Ohm/km

 

Cable 6 mm2 H1Z2Z2-K Ro

Nexans ref. 10043332

  • Packaging: Drum (1000m)
  • Approximate weight: 71 kg/km
  • Conductor cross-section: 6 mm²
  • Conductor diameter: 3.15 mm
  • Insulation sheath thickness: 0.8 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer diameter: 6.3 mm
  • Nominal outer sheath thickness: 0.8 mm
  • Ampacity: 70.0 A
  • Max. DC resistance of the conductor at 20°C: 3.39 Ohm/km

 

Description

Description

Standards

  • International
    EN 50618

Application

Supply of low voltage 1.5 kV DC circuits in photovoltaic solar energy installations where weather resistance characteristics are required.

Ideal for connection between strings of photovoltaic solar panels and as a main power supply for connecting DC / AC inverters.

Construction

Conductor

Flexible soft tinned copper conductor class 5

Insulation

Thermostable compound free of halogens (HF) and low smoke emission (LS) toxic and corrosive.

Jacket

Halogen free (HF), flame retardant (FR) and UV resistant thermosetting compound, suitable for AD7 immersion.

Applicable Standards

  • EN 50618
  • IEC 62930

Certificate

RETIE N° 07225

RETIE N° 07215

Operating Temperature

90°C / 120°C (Max. 20.000 h)

Max. conductor temperature based on EN 60216-1:

-40°C to +120°C

Ambient temperature range according to EN 50618:

-40°C to +90°C

Operating Voltage

1 kV AC

1.5 kV DC

Max. Operation Voltage

1.2 kV AC

1.8 kV DC

Ampacity Conditions

  • Current capacity a single cable outdoors, at 60 ºC According to the norm in 50618- table A.3(see Table A.4 for
    other ambient temperatures)
  • The expected period of use at a maximum conductor temperature of 120°C and at a maximum ambient temperature of 90°C is limited to 20,000 h.
  • Data indicated in this table are subject to normal manufacturing tolerances.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Flexible
Conductor material
Tinned annealed copper
Halogen free
IEC 60754-1, UNE-EN 50267
Insulation
XLPE
Outer sheath
XLPE

Dimensional characteristics

Dimensional characteristics

Number of cores
1

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
1.0/1.0 (1.2) kV AC 1.5/1.5 (1.8) kV DC

Usage characteristics

Usage characteristics

Corrosive or Polluting Substances
Condition AF 3 (intermittent accidential) acc. to HD 60364-5-52
Flame retardant
IEC 60332-1-2
Outdoor Use
Condition AN 3 (high solar radiation), permanent acc. to EN 50565-1:2014
Ozone resistance
EN 50396:2005
Resistance to vibrations
Condition AH 3 (sever industrial conditions) acc. to HD 60364-5-52
Smoke density
IEC 61034-2
U.V resistance
EN 50289-4-17 method A, for 720h
Weather resistance
Excellent

Resources

Resources

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close