CABLE SOLAR AL 1350 DC XLPE/HFFR
CABLE SOLAR AL 1350 DC XLPE/HFFR
1350 aluminum cable, XLPE insulated and HFFR sheath
Read moreCABLE AL 150 MM2
Nexans ref. 10041433
- Approximate weight: 596 kg/km
- Conductor cross-section: 150 mm²
- Conductor diameter: 8.69 mm
- Insulation sheath thickness: 1.1 mm
- Nominal insulation thickness: 1.4 mm
- Nominal outer diameter: 19.85 mm
- Ampacity: 376.0 A
- Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
- Water penetration:
CABLE AL 240 MM2
Nexans ref. 10046668
- Approximate weight: 944 kg/km
- Conductor cross-section: 240 mm²
- Conductor diameter: 8.01 mm
- Insulation sheath thickness: 1.22 mm
- Nominal insulation thickness: 1.75 mm
- Nominal outer diameter: 24.94 mm
- Ampacity: 494.0 A
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- Water penetration:
CABLE AL 35 MM2
Nexans ref. 10041410
- Approximate weight: 191 kg/km
- Conductor cross-section: 35 mm²
- Conductor diameter: 7.52 mm
- Insulation sheath thickness: 0.92 mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer diameter: 10.9 mm
- Ampacity: - A
- Max. DC resistance of the conductor at 20°C: 0.868 Ohm/km
- Water penetration:
CABLE AL 50 MM2
Nexans ref. 10041411
- Approximate weight: 251 kg/km
- Conductor cross-section: 50 mm²
- Conductor diameter: 8.08 mm
- Insulation sheath thickness: 0.92 mm
- Nominal insulation thickness: 1.0 mm
- Nominal outer diameter: 12.2 mm
- Ampacity: 200.0 A
- Max. DC resistance of the conductor at 20°C: 0.641 Ohm/km
- Water penetration: <3%
CABLE AL 95 MM2
Nexans ref. 10041412
- Approximate weight: 316 kg/km
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.62 mm
- Insulation sheath thickness: 1.0 mm
- Nominal insulation thickness: 1.1 mm
- Nominal outer diameter: 16.18 mm
- Ampacity: 294.0 A
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- Water penetration:
Cable AL 25 MM2
Nexans ref. 10041409
- Approximate weight: 139 kg/km
- Conductor cross-section: 25 mm²
- Conductor diameter: 5.91 mm
- Insulation sheath thickness: 0.92 mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer diameter: 10.15 mm
- Ampacity: 141.0 A
- Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
- Water penetration:
Description
Description
Standards
-
ProductHD 603; IEC 60228; IEC 60502-1
-
TestEN 60332-1-2; EN 61034
Aplication
- For use in photovoltaic systems with nominal voltage of 1.8 kV DC.
- Plants photovoltaic roof systems and photovoltaic parks.
- Secondary distribution in low voltage.
- Suitable for direct burial.
Construction
Conductor
Aluminum conductor 1350, class 2.
Insulation
Crosslinked polyethylene XLPE Halogen-free.
Jacket
Halogen free polyolefin, flame retardant
Applicable Standards
- IEC 60228
- IEC 60502-1
- UNE 21123-4
- HD 603-1
- UNE -EN 60332-1-2
Certificate
RETIE and NORMA N° 07
Operating Temperature
90°C
Operating Voltage
1 KV AC.
1.5 kV DC.
Max. DC Operation Voltage
1.2 kV AC
1,8 kV DC
Marking
NEXANS COLOMBIA. < Calibre >MM2 AL FREETOX XLPE/HFFR 0,6KV-1,8 kv DC 90°C (M)
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Empaque
Carretes de 500m. +/- 5%
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania