18 AWG - 1000 kcmil

Description

Description

Standards

  • Product
    ICEA S-95-658; NTC 1099-1

Application

Secondary distribution in low voltage. Indoor installations of industrial, commercial and residential buildings that must continue to operate in case of exposure to fire. Suitable for installation in trays, compliance with Tray Cable (TC) flame test. Fire resistance test in accordance with IEC 60331.

Fire Resistance Test (Circuit Integrity): The flame must have sufficient power so that the cable surface reaches a temperature of 750°C 10 minutes after the fire is applied and this must be maintained for 120 minutes.

During this time and up to 15 minutes after the fire is extinguished, the conductors must be energized at Nominal Voltage.

Note: Any other application or use not described above is considered prohibited.

Construction

Conductor

Soft copper flexible conductor in size from 18 AWG - 2000 kcmil, covered with flame retardant mica tape.

Insulation

Cross-linked polyethylene (XLPE) compound.

Jacket

Halogen-free, low-smoke, flame retardant polyolefin compound (HFFR-LS).

Applicable Standards

  • NTC 1099-1
  • ICEA S-95-658

Certificate

CIDET N°02485

CIDET N°CP25_AA00633

Operating Voltage

600 V - 2000 V.

Identification

Single Cable: Insulation in natural base color and Black Jacket.

Muticonductor Cable: Insulation in colors and Black Jacket.

Packaging Unit

500 m or 1000 m reels. Other packaging units available upon request.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Conductor flexibility
Conductor shape
Bunched Wires
Insulation
XLPE
Halogen free
Yes
Outer sheath
HFFR (Halogen Free Flame Retardant)

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
- mm²
Outer Diameter
- mm
Approximate weight
- kg/km
Nominal insulation thickness
- mm
Nominal outer diameter
- mm
Number of cores
-

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
- Ohm/km
Rated Voltage Uo/U (Um)
Permissible current rating buried/duct 20°C
- A
Perm. current rating in air 30°C - flat formation
- A

Mechanical characteristics

Mechanical characteristics

Abrasion resistance
Good

Usage characteristics

Usage characteristics

Fire resistant
IEC 60331
Flame retardant
IEC 60332-3-24 Cat. C
Smoke density
IEC 61034-2
Maximum operating temperature
90 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close