4x14 AWG

Description

Description

Application

Multiconductor Power Cable WOC "Water Oxygenator Cable", whose combination of insulation and jacket results in excellent flexibility and mechanical resistance. Especially recommended for use in the electrical supply of oxygenation systems applied in shrimp ponds.

Its design allows it to be permanently submerged in water, operating efficiently in the oxygenation required for the maintenance of aquatic species. Additionally, this cable is prepared to withstand varied outdoor conditions, including exposure to UV radiation, changes in water temperature and other adverse atmospheric conditions.

Compliance with the flame propagation test according to the IEC 60332-1-2 standard is guaranteed.

 

Construction

Conductor

Extra-flexible soft copper conductors.

Insulation

Thermoset compound type Ethylene propylene Rubber (EPR), for a maximum temperature of 90°C. Compound free of hazardous substances (RoHS).

Jacket

Outer jacket with thermoplastic Elastomer compound (TPE), Halogen free (HF), flame retardant (FR), resistant to solar rays (SR) and abrasion.

Standard

ICEA S-95-658

Certificate

CIDET  No 00408

Operating Temperature

90°C

Operating Voltage

600 V 

Identification

Black insulation with number printing, Black jacket.

Ampacity Conditions (*)

  • ​Current capacity for 90°C conductor temperature, 30°C ambient temperature. No more than three current-carrying conductors in a conduit or raceway. NTC 2050, Table 310.15(B)(16).
  • The data indicated in this table are subject to normal manufacturing tolerances.

NOTE:

  • The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
  • Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Flexible Copper
Conductor flexibility
Class J
Conductor shape
Bunched Wires
Insulation
EPR
Outer sheath
TPE
Halogen free
Yes

Dimensional characteristics

Dimensional characteristics

Conductor diameter
10.97 mm
Conductor cross-section
2.08 mm²
Approximate weight
164 kg/km
Nominal insulation thickness
0.76 mm
Nominal outer diameter
10.97 mm
Nominal outer sheath thickness
1.14 mm
Number of cores
4

Electrical characteristics

Electrical characteristics

Ampacity
25.0 A
Max. DC resistance of the conductor at 20°C
8.613 Ohm/km
Maximum operating voltage
600 V

Mechanical characteristics

Mechanical characteristics

Abrasion resistance
Excellent
Minimum repeated bending diameter
44 mm
Maximum Pulling Tension
0.59 kN

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
U.V resistance
Yes
Moisture resistance
Ensayo calor humedo según IEC 60068-2-78, 90°C, 1000 h, 85% mínimo.
Maximum operating temperature
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*