CABLES LIBRES DE HALÓGENOS LHFR-LS Cu 600V 90°C

Products

14AWG

Nexans ref. 209109

  • Approximate weight: 28.01 kg/km
  • Conductor cross-section: 2.08 mm²
  • Conductor diameter: 1.793 mm
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 3.39 mm
  • Ampacity: 25.0 A
  • Max. DC resistance of the conductor at 20°C: 8.629 Ohm/km

 

12AWG

Nexans ref. 209110

  • Approximate weight: 40.71 kg/km
  • Conductor cross-section: 3.31 mm²
  • Conductor diameter: 2.258 mm
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 3.86 mm
  • Ampacity: 30.0 A
  • Max. DC resistance of the conductor at 20°C: 5.457 Ohm/km

 

10AWG

Nexans ref. 209111

  • Approximate weight: 60.17 kg/km
  • Conductor cross-section: 5.26 mm²
  • Conductor diameter: 2.849 mm
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 4.45 mm
  • Ampacity: 40.0 A
  • Max. DC resistance of the conductor at 20°C: 3.417 Ohm/km

 

8AWG

Nexans ref. 209112

  • Approximate weight: 98.64 kg/km
  • Conductor cross-section: 8.37 mm²
  • Conductor diameter: 3.39 mm
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 5.77 mm
  • Ampacity: 55.0 A
  • Max. DC resistance of the conductor at 20°C: 2.142 Ohm/km

 

6AWG

Nexans ref. 209113

  • Approximate weight: 161.76 kg/km
  • Conductor cross-section: 13.3 mm²
  • Conductor diameter: 4.28 mm
  • Nominal insulation thickness: 1.52 mm
  • Nominal outer diameter: 7.44 mm
  • Ampacity: 75.0 A
  • Max. DC resistance of the conductor at 20°C: 1.346 Ohm/km

 

4AWG

Nexans ref. 209114

  • Approximate weight: 240.54 kg/km
  • Conductor cross-section: 21.2 mm²
  • Conductor diameter: 5.4 mm
  • Nominal insulation thickness: 1.52 mm
  • Nominal outer diameter: 8.56 mm
  • Ampacity: 95.0 A
  • Max. DC resistance of the conductor at 20°C: 0.847 Ohm/km

 

2AWG

Nexans ref. 209115

  • Approximate weight: 362.98 kg/km
  • Conductor cross-section: 33.6 mm²
  • Conductor diameter: 6.81 mm
  • Nominal insulation thickness: 1.52 mm
  • Nominal outer diameter: 9.97 mm
  • Ampacity: 130.0 A
  • Max. DC resistance of the conductor at 20°C: 0.532 Ohm/km

 

1/0AWG

Nexans ref. 209117

  • Approximate weight: 584.8 kg/km
  • Conductor cross-section: 53.5 mm²
  • Conductor diameter: 8.93 mm
  • Nominal insulation thickness: 2.03 mm
  • Nominal outer diameter: 13.11 mm
  • Ampacity: 170.0 A
  • Max. DC resistance of the conductor at 20°C: 0.335 Ohm/km

 

2/0AWG

Nexans ref. 209118

  • Approximate weight: 726.86 kg/km
  • Conductor cross-section: 67.4 mm²
  • Conductor diameter: 10.02 mm
  • Nominal insulation thickness: 2.03 mm
  • Nominal outer diameter: 14.2 mm
  • Ampacity: 195.0 A
  • Max. DC resistance of the conductor at 20°C: 0.266 Ohm/km

 

3/0AWG

Nexans ref. 209119

  • Approximate weight: 889.61 kg/km
  • Conductor cross-section: 85.03 mm²
  • Conductor diameter: 11.25 mm
  • Nominal insulation thickness: 2.03 mm
  • Nominal outer diameter: 15.43 mm
  • Ampacity: 225.0 A
  • Max. DC resistance of the conductor at 20°C: 0.211 Ohm/km

 

4/0AWG

Nexans ref. 209120

  • Approximate weight: 1107.72 kg/km
  • Conductor cross-section: 107.2 mm²
  • Conductor diameter: 12.64 mm
  • Nominal insulation thickness: 2.03 mm
  • Nominal outer diameter: 16.82 mm
  • Ampacity: 260.0 A
  • Max. DC resistance of the conductor at 20°C: 0.167 Ohm/km

 

250KCMIL

Nexans ref. 209121

  • Approximate weight: 1315.99 kg/km
  • Conductor cross-section: 127 mm²
  • Conductor diameter: 13.25 mm
  • Nominal insulation thickness: 2.41 mm
  • Nominal outer diameter: 18.21 mm
  • Ampacity: 290.0 A
  • Max. DC resistance of the conductor at 20°C: 0.142 Ohm/km

 

Description

Description

Centelsa by Nexans Halogen-Free cables are part of the Nexans Fire Safety offer that allows you to protect people's lives, anticipate risks and secure assets in the event of fires.

Our Halogen-Free Cables do not spread fire, have low smoke emission, do not emit toxic gases, have a maximum operating temperature of 90°C and more Slidable in sizes from 14 AWG to 10 AWG.

Application

Cables for low voltage electrical energy distribution, installations in buildings, inside premises, control panels and electronic circuits. Suitable for places with a high concentration of people, where halogen-free conductors and low smoke emission are required, which in the event of a fire will not generate toxic or corrosive gases that may affect the health of people and the condition of equipment and circuits electronics. The cables can be used for installations mentioned in NTC 2050 Article 310.

Suitable for installation in cable trays according to RETIE article 20.3, literal J, from 12 AWG gauge and larger.

For sizes from 14 AWG to 10 AWG, now more sliding, generating benefits such as:

  • Easy to install, even in conduits with multiple bends.
  • Reduces friction.
  • Less pulling tension effort.
  • Savings in installation time.
  • Does not require the use of lubricants.

Construction

Conductor

Soft copper conductor.

Insulation

Free halogen, flame retardant and low smoke emission opaque, dense, toxic and corrosive thermoplastic compound.

Applicable Standards

NTC 6182

Certificate

RETIE  N° 07511 / RETIE N° 05915

 

Operating Temperature

90°C, obtaining greater current capacity compared to a 75°C cable, more efficient electrical design.

Operating Voltage

600V

Marking

CENTELSA by NEXANS < Calibre AWG / Kcmil >  Cu LHFR-LS 600 V 90°C CT - HECHO EN COLOMBIA [M].

Ampacity Conditions

  • Ampacity to 90 °C conductor temperature, 30°C ambient temperature. No more than three current carrying condutores in a duct or pipe. According to NTC 2050, Table 310.15(B)(16).

 

NOTE:

  • The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
  • Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities. 

Nexans Fire Safety

LHFR-LS Cables

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Class B
Conductor material
Soft copper
Halogen free
IEC 60754-1
Insulation
Halogen free polyolefin

Dimensional characteristics

Dimensional characteristics

Number of cores
1

Electrical characteristics

Electrical characteristics

Operating voltage
600 V

Mechanical characteristics

Mechanical characteristics

Abrasion resistance
Good

Usage characteristics

Usage characteristics

Fire retardant
Vertical Tray - Method 1 (UL 2556/9.6)
Gases corrosivity
IEC 60754-1; IEC 60754-2
Gases toxicity
Low toxicity to IEC 60684-2
Maximum operating temperature
90 °C
Smoke density
Zero Smoke Emission IEC 61034-2

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close