THHN/THWN-2 600V CT RoHS CABLE
THHN/THWN-2 600V CT RoHS CABLE
Soft copper conductor, PVC insulated and jacket in nylon.
Read moreC.500kcmil
Nexans ref. 10011452
- Conductor diameter: 19.82 mm
- Conductor cross-section: 253.35 mm²
- Approximate weight: 2383.82 kg/km
- Nominal insulation thickness: 1.52 mm
- Nominal outer diameter: 23.73 mm
- Max. DC resistance of the conductor at 20°C: 0.071 Ohm/km
- Ampacity: 430.0 A
C.350kcmil
Nexans ref. 10011449
- Conductor diameter: 16.57 mm
- Conductor cross-section: 177.35 mm²
- Approximate weight: 1711.76 kg/km
- Nominal insulation thickness: 1.52 mm
- Nominal outer diameter: 20.46 mm
- Max. DC resistance of the conductor at 20°C: 0.101 Ohm/km
- Ampacity: 350.0 A
C.250kcmil
Nexans ref. 10011445
- Conductor diameter: 14.05 mm
- Conductor cross-section: 126.68 mm²
- Approximate weight: 1250.2 kg/km
- Nominal insulation thickness: 1.52 mm
- Nominal outer diameter: 17.86 mm
- Max. DC resistance of the conductor at 20°C: 0.142 Ohm/km
- Ampacity: 290.0 A
C.4/0AWG
Nexans ref. 10011403
- Conductor diameter: 12.38 mm
- Conductor cross-section: 107.22 mm²
- Approximate weight: 1032.96 kg/km
- Nominal insulation thickness: 1.27 mm
- Nominal outer diameter: 15.74 mm
- Max. DC resistance of the conductor at 20°C: 0.167 Ohm/km
- Ampacity: 260.0 A
C.3/0AWG
Nexans ref. 10012629
- Conductor diameter: 11.44 mm
- Conductor cross-section: 85.03 mm²
- Approximate weight: 836.57 kg/km
- Nominal insulation thickness: 1.27 mm
- Nominal outer diameter: 14.35 mm
- Max. DC resistance of the conductor at 20°C: 0.211 Ohm/km
- Ampacity: 225.0 A
C.2/0AWG
Nexans ref. 10011391
- Conductor diameter: 9.82 mm
- Conductor cross-section: 67.44 mm²
- Approximate weight: 669.1 kg/km
- Nominal insulation thickness: 1.27 mm
- Nominal outer diameter: 13.12 mm
- Max. DC resistance of the conductor at 20°C: 0.266 Ohm/km
- Ampacity: 195.0 A
C.1/0AWG
Nexans ref. 10011381
- Conductor diameter: 8.76 mm
- Conductor cross-section: 53.51 mm²
- Approximate weight: 540.17 kg/km
- Nominal insulation thickness: 1.27 mm
- Nominal outer diameter: 12.03 mm
- Max. DC resistance of the conductor at 20°C: 0.335 Ohm/km
- Ampacity: 170.0 A
C.2AWG
Nexans ref. 10011383
- Conductor diameter: 7.09 mm
- Conductor cross-section: 33.63 mm²
- Approximate weight: 344.94 kg/km
- Nominal insulation thickness: 1.02 mm
- Nominal outer diameter: 9.72 mm
- Max. DC resistance of the conductor at 20°C: 0.532 Ohm/km
- Ampacity: 130.0 A
C.4AWG
Nexans ref. 10011394
- Conductor diameter: 5.61 mm
- Conductor cross-section: 21.15 mm²
- Approximate weight: 223.35 kg/km
- Nominal insulation thickness: 1.02 mm
- Nominal outer diameter: 8.23 mm
- Max. DC resistance of the conductor at 20°C: 0.847 Ohm/km
- Ampacity: 95.0 A
C.6AWG
Nexans ref. 10011405
- Conductor diameter: 4.44 mm
- Conductor cross-section: 13.3 mm²
- Approximate weight: 140.64 kg/km
- Nominal insulation thickness: 0.76 mm
- Nominal outer diameter: 6.47 mm
- Max. DC resistance of the conductor at 20°C: 1.346 Ohm/km
- Ampacity: 75.0 A
C.8AWG
Nexans ref. 10011413
- Conductor diameter: 3.52 mm
- Conductor cross-section: 8.37 mm²
- Approximate weight: 92.88 kg/km
- Nominal insulation thickness: 0.76 mm
- Nominal outer diameter: 5.53 mm
- Max. DC resistance of the conductor at 20°C: 2.142 Ohm/km
- Ampacity: 55.0 A
C.10AWG
Nexans ref. 10011421
- Conductor diameter: 2.79 mm
- Conductor cross-section: 5.26 mm²
- Approximate weight: 56.88 kg/km
- Nominal insulation thickness: 0.51 mm
- Nominal outer diameter: 4.21 mm
- Max. DC resistance of the conductor at 20°C: 3.417 Ohm/km
- Ampacity: 40.0 A
C.12AWG
Nexans ref. 10011430
- Conductor diameter: 2.22 mm
- Conductor cross-section: 3.31 mm²
- Approximate weight: 35 kg/km
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 3.36 mm
- Max. DC resistance of the conductor at 20°C: 5.457 Ohm/km
- Ampacity: 30.0 A
C.14AWG
Nexans ref. 10011439
- Conductor diameter: 1.77 mm
- Conductor cross-section: 2.08 mm²
- Approximate weight: 23 kg/km
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 2.89 mm
- Max. DC resistance of the conductor at 20°C: 8.629 Ohm/km
- Ampacity: 25.0 A
Description
Description
Standards
-
NationalASTM B 3; ASTM B 8; NTC 1332; NTC 307; NTC 359; UL 83
Application
Low voltage electrical energy distribution; for use in electrical wiring of buildings, feeder circuits, branches and secondary industrial, commercial and residential indoor networks. Special for installations in abrasive sites or sites contaminated with oil, grease, gasoline, and other chemical substances.
They are suitable for installation in ducts, pipes, boards, and cable trays according to RETIE article 20.3 literal J, from 12 AWG gauge and larger.
Construction
Conductor
Soft copper conductor, concentric stranded, Class B.
Insulation
Polyvinyl chloride (PVC), flame retardant (FR), resistant to heat, abrasion and humidity, resistant to sunlight (SR) in black, free of hazardous substances (RoHS).
Jacket
External cover in polyamide (nylon), resistant to gasoline and oils (GR II).
Applicable Standards
• UL 83, NTC 1332
Certificate
RETIE N° 01864
RETIE N° 00406
Operating Temperature
90°C dry and wet places.
Operating Voltage
600V
Identification
Insulation in colors according to the manufacturing standard.
Ampacity Conditions
- Current capacity for 90°C conductor temperature, 30°C ambient temperature. No more than three current-carrying conductors in a conduit or raceway. NTC 2050, Table 310.15(B)(16).
- The data indicated in this table are subject to normal manufacturing tolerances.
NOTE:
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Find a Distributor
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania